Vascular · 120-minute faculty-led lab

Open Abdominal Aortic Aneurysm Repair

Tube Graft Reconstruction · Two graft-to-aorta anastomoses on one connected model

Open Abdominal Aortic Aneurysm Repair simulation overview illustration

Step 1 illustration: Prepare the graft, clinical anatomy compared with the Real Bleed model
Step 1 of 4

Prepare the graft

Clinical context
Identify the proximal and distal cuffs within the opened aneurysm sac.
Rehearse on the model
Align a short tube graft between the connected aortic ends.
Check
Match caliber; allow access to both suture lines without unnecessary tissue length.
Step 2 illustration: Proximal join, clinical anatomy compared with the Real Bleed model
Step 2 of 4

Proximal join

Clinical context
Join the graft to the proximal aortic cuff.
Rehearse on the model
Complete the left graft-to-aorta anastomosis; the right end remains open.
Check
Inspect posterior-wall apposition and stitch spacing. Avoid catching the opposite wall. Keep flow off.
Step 3 illustration: Distal join, clinical anatomy compared with the Real Bleed model
Step 3 of 4

Distal join

Clinical context
Join the graft to the distal aortic cuff above the bifurcation.
Rehearse on the model
Complete the right join while retaining the proximal repair.
Check
Inspect both interfaces for gaps, narrowing, tension and twist. Avoid graft kinking.
Step 4 illustration: Test and revise, clinical anatomy compared with the Real Bleed model
Step 4 of 4

Test and revise

Clinical context
Assess hemostasis and distal perfusion before closure.
Rehearse on the model
Test at a faculty-validated setting. Locate leakage, stop flow, revise and retest.
Check
Review both joins and outlet flow; a dry seam alone does not establish an unobstructed lumen.
What the model represents

Scope and
limitations.

The model rehearses two graft-to-aorta joins. It does not reproduce aneurysm wall behavior, lumbar backbleeding, clamp physiology or renal ischemia. Clinical repair retains the opened aneurysm sac for graft coverage. Bench interposition is a simplified skills exercise, not the full operation.

Educational simulation concept for faculty review. The model does not establish clinical competence or patient outcomes. Illustrations may depict equipment not included in the kit.